Skip to main content
Version: 2.9.0

Powerscale OneFS Upgrade

Before You Begin

Minor vs Major Release Upgrades

Post Powerscale OneFS Upgrade Steps

Eyeglass DR Edition

  1. Restart the SCA Service:
    • SSH to the appliance as the admin user.
    • Switch to the root user:
      • Run sudo -s.
      • Enter the admin password when prompted.
    • Restart the SCA service:
      • Run systemctl restart sca.
    • Wait 30 minutes for the service to stabilize.
    • Log in to the GUI and verify there are no errors in the Jobs or DR Dashboard.

Data Security, Easy Auditor, and Performance Auditor

  1. Restart the ECA Cluster:
    • Log in to node 1 of the ECA cluster.
    • Bring the cluster down:
      • Run ecactl cluster down.
    • Wait until all shutdown steps are complete.
    • Bring the cluster back up:
      • Run ecactl cluster up.
    • Wait for all startup steps to complete.
  2. Verify Managed Services:
    • Log in to Eyeglass.
    • Open the Managed Services icon.
    • Verify that all nodes show green status (you may need to wait 5 minutes).
  3. Run and Verify Security Checks:
    • Data Security:
      • Run Security Guard.
      • Verify that it completes successfully.
    • Easy Auditor:
      • Run Robot Audit.
      • Verify that it completes successfully.
    • Performance Auditor:
      • Open the tool icon.
      • Verify that performance data is displayed.
  4. Done